Documentation:

RN-101
Voltage relay

APPLICATIONS

The RN-101 voltage relay is designed to de-energize an industrial/appliance single-phase 220V/50Hz load of 3.5 kWt (up to 16A) power when there are unallowable voltage variations in the mains.

Rn101
  1. control for Umax setting;
  2. control for Umin setting;
  3. control for Ton setting;
  4. green LED indicating that voltage exists in the mains;
  5. green LED indicating that load is ON.

DESCRIPTION

The relay is connected in series with load, i. e. the relay is plugged in at a socket-outlet directly and the load is thrown on at a female connector of the relay.

When the relay trips due to unallowable overvoltage/undervoltage, a switching device built-in the relay de-energizes the load. On return to normal operating conditions when the voltage parameters regenerate, the relay will reset automatically and the load will be energized. The automatic reset delay (Ton) is set by user.

To provide immunity to minor and/or short-term undervoltage and to avoid excessive trippings of the relay when Umin is reached the fixed trip delay is provided .

T he relay trips after 0.1 sec fault delay has expired when deep undervoltage is more than 30V below Umin setting.

Before plugging in the relay user must set adjustable trip settings by the front-panel contact arms of potentiometers. It’s necessary to set Umax threshold and Umin threshold values for the relay to trip as well as the automatic reset delay according to the device that the relay is to protect (reset delay for air-conditioners, refrigerators and compressor installations is no less than 3-4 min, reset delay for other instrumentation is according to their operating instructions).

Adjustable trip settings are set by user. It's recommended to set trip settings before the relay is plugged in.

After the relay is plugged in, the load will be on when the initial time delay equal to the potentiometer-set delay Ton, has expired.

The relay has two LEDs indicating that the mains voltage exists and that voltage is present on the relay output (i. e. on the protected device): when the relay trips this LED goes out.

SPECIFICATION

Nominal voltage, V 220
Mains frequency, Hz 48-52
Adjustable trip range
-for Umin threshold, V 160-210
-for Umax threshold, V 230-280
-automatic reset delay, sec 5-900
Fixed trip delay when Umax is reached, sec 0.5
Fixed trip delay when Umin is reached, sec 12
Fixed trip delay when U is 30V below Umin/above Umax, sec 0.1
Maximum switched current, A, ≥ 16
Trip voltage threshold determination accuracy for U, V to 3
Safe operating voltage,V 400
Transient withstand, V 450
Operating temperature range, °C -25 - + 55
Storage temperature, °C -45 - + 70
Total input current consumption, mA to 15
Life, operations, ≥ 100000

Trip setting ranges and their fixed values can be changed at the customer’s request.

MAIN FEATURES

  1. a wide range of adjustable trip thresholds (Umax, Umin, reset delay) is provided;
  2. when Umin is reached the relay trips with fixed trip delay;
  3. the relay trips with 0.1 sec accelerated time delay when deep undervoltage/abrupt overvoltage is more than 30V below/above Umin/Umax settings;
  4. LED indication for relay status signaling that input voltage and output voltage is present;
  5. trip/reset hysteresis for Umax/Umin is approximately 5V. It means that if the relay had tripped due to voltage drop below Umin threshold and the load was de-energized, the relay will reset automatically and energize the load when the voltage exceeds 5V above Umin threshold (reaching the level set by hysteresis) with reset delay Ton;
  6. compactness and small weight of the relay.